DIN24342 - 16mm - 40mm - 5000 PSI

  • Standard D03 interface
  • SAE O-ring ports for access to P&T
  • Removable orifice plug options
  • Ships standard with an orifice installed in the “P” port & according to Plug option #1
Applications

Dump Valve  or ON/OFF Valve

Can be used as a dump valve by Connecting ‘X’ to the ‘B’ port (side of insert) & Connecting ‘Y’ to drain. The diagrams to the  right show the two different plug options. Plug option #1  will allow the valve to dump in the de-energized state & Plug option #2 will allow the valve to dump in the energized state.

Note: If port “A” is connected to a working port, then connecting ‘X’ to the ‘B’ port as shown above does not prevent pressure at A from overcoming the forces acting to keep the valve closed. Flow could occur from A to B. To prevent this use a separate pilot pressure for X.

General Layout

Only one orifice installed in ‘P’ port of D03 interface. Other orifices are optional.

Order Code